UPS Monitoring Module

  • Small, ruggedized enclosure with wall mount brackets (DIN rail optional)
  • Hi speed data communication using CAN2.0 interface for M2M communication
  • 11 channels ADC having sampling speeds up to 10ksps
  • Small form factor with waterproof NEMA enclosure option
  • Accessible without a public IP
  • Network UPS tolls for UPS monitoring and Management
  • PDU and RPS management
  • Hotkey for in-session power menu
  • Monitors and assess the state of state of Rectifiers by monitoring the voltage and current of batteries as well as the total load of Rectifier
  • Fully scalable architecture to monitor new Rectifier installations without modifying the current installations
  • Wide AC and DC input voltage range
  • Optional data logging capabilities
  • 4 Digital I/O , 2RS232 ports, TCP access (RS422, RS485 option)
  • Configurable for standalone UPS Monitoring System with GSM/GPRS/Ethernet/CDMA connectivity.
  • Online and offline data storage option
  • Enhanced security for public internet connections using VPN, SSH, AAA
  • Programmable alert notifications and alarms
  • Industrial grade solution for use in demanding and tough environments
Parameter Type Operating conditions Minimum Typical Maximum Unit
Operating Voltage 12.5 13.5 17 Volts
Power consumed 1.5 1.5 1.9 Watts
Number of Temperature Sensors 1 Units
Temp Measurement Range 0°C to +100°C 0°C +100°C °C
Thermometer accuracy 0°C to +100°C ±0.2 ±0.5 ±1 °C
Battery Bank Voltage DC 0 560 VDC
Battery Bank Current -500 500 DCI
UPS Phase Voltages 3 phase, 4 Wire 0 220 400 VAC
Voltage measurement accuracy 0°C to +100°C 0.01 VAC
UPS Phase Currents 0 800A ACI
Current measurement accuracy 0°C to +100°C 0.01 Amp (AC)
ADC Resolution 10 Bits
ADC Frequency 500 8000 KHz
M2M communication UART 9600 Bps
M2M communication CAN Bus 125000 Bps
  • EN55024: 1998+A1:2001+A2:2003
  • IEC61000-4.2:1995 ESD 8kV Air Discharge (Direct), 4kV Contact Discharge (Direct/Indirect)
  • IEC61000-4.3:1995 Radiated Immunity 3.0 V/m, 1kHz, AM Sine Wave at 80%
  • IEC61000-4.5: 1995 Surge Immunity 1.0kV Common Mode, 1.0KV Differential Mode
  • IEC61000-4.6: 1996 Conducted Immunity 3.0Vrms, 80% AM modulated (1kHz)
  • IEC61000-4.11: 1994 Voltage Dips and Interrupts (>95%, 0.5periods), (30%, 25 periods), (>95%, 250 periods)
  • ROHS
  • CE (2011/65/EU)
  • Isolation
  • Serial Port: 4kV ESD protection on RS232 and CAN Transceivers
  • Optional Chassis ground for signal integrity (Applicable for Metal casing models only)
  • 4kV ESD protection between Analog front end and Processor Core.
  • Complete Isolation between Analog front end and processor core preserving signal integrity and reducing noise
  • MOVs to protect against high voltage impulses