Master Control Unit
- Small, ruggedized enclosure with wall mount, rack mount options (DIN rail optional)
- Serial, and Digital I/O connectivity in every single device (Optional Ethernet/CDMA)
- RS232, Serial ports, TCP access, COM port redirection (RS422/485 optional)
- 21xAnalog ports with Sampling rates up to 10ksps
- Monitoring of Fuel Tanks up to 22000 liters*
- 4xDigital outputs for controlling BTS power sources
- Split core CTs for easy installations
- 6x Digital inputs for manual control of power sources
- Self-Recovery Algorithms to make the system fail safe
- Automated detachment from Power Source control to ensure uninterrupted power to the system in case of system failure
- Digital Alarms and ACP-Feedback provision for DDF patch for easy integration with Client’s NOC
- Access the unreachable-manage equipment behind remote firewalls and VPNs
- Monitor and control environment of the data centers and remote sites
- Enhanced Security for connection over public cellular network, VPN, SSH, AAA
- Scan remote data and create proactive custom solutions
- Easy troubleshooting with ON and off line data logging with time stamps
- Even tracking and corrective actions- alert notification, Custom auto response
- High data speeds for back up remote network connection
- Serial port Management
- Tunneled Serial Bridging
- Port triggers with SNMP and email alerts
- Offline data logging (Syslog, NFS, CIFS0
- Multiple users per port (with port sniffing)
- Access by TCP port
- Telnet/ Unauthenticated Telnet SSH/ Raw TCP connect
- RFC2217- Port redirection
- No limits on number of hosts being concurrently accessed through one tunnel
- No limits on number of clients who can access the one cellular router
Parameter | Operating conditions | Minimum | Typical | Maximum | Unit |
Operating Voltage | – | 12.5 | 13.5 | 17 | Volts |
Power consumed | – | 1.5 | 1.5 | 1.9 | Watts |
Operating Temperature | – | -20°C | – | +55°C | |
Storage Temperature | – | -30°C | +85°C | ||
Number of Temperature Sensors | – | – | 1 | – | Units |
Temperature Measurement Range | 0°C to +100°C | 0°C | – | +100°C | °C |
Thermometer accuracy | 0°C to +100°C | ±0.2 | ±0.5 | ±1 | °C |
Number of Digital Inputs | – | – | 10 | – | Units |
Number of Spare Ports | – | – | 5 | – | – |
ADC Frequency | – | – | 500 | 8000 | KHz |
(UART) M2M communication | – | – | 9600 | – | Bps |
- EN55024: 1998+A1:2001+A2:2003
- IEC61000-4.2:1995 ESD 8kV Air Discharge (Direct), 4kV Contact Discharge (Direct/Indirect)
- IEC61000-4.3:1995 Radiated Immunity 3.0 V/m, 1kHz, AM Sine Wave at 80%
- IEC61000-4.5: 1995 Surge Immunity 1.0kV Common Mode, 1.0KV Differential Mode
- IEC61000-4.6: 1996 Conducted Immunity 3.0Vrms, 80% AM modulated (1kHz)
- IEC61000-4.11: 1994 Voltage Dips and Interrupts (>95%, 0.5periods), (30%, 25 periods), (>95%, 250 periods)
- ROHS
- CE (2011/65/EU)